Necesitas Ayuda?+52 55 61 22 77 00
Correo: ventas@omegaautomation.com.mx

1783-US6T2H, Stratix 2000 6T+2H Port Unmanaged Switch

MXN $42,869.00 - (IVA Incluido) + Envío

Sin existencias

Stratix 2000 6T+2H Port Unmanaged Switch

SKU: 1783-US6T2H

Technical Specifications

Mechanical

Width 106.68 cm
Height 129.54 cm
Depth 159.26 cm
Screw torque, alarm terminal 0.56 Nm
Screw torque, ground terminal 0.4 Nm
Screw torque, power terminal 0.56 Nm

Electrical

Number of ports 10/100/1000 Mbps RJ45 2
Layer 2 No
Layer 3 No
Manageable No
Pulse (digital) output 24 W
Power dissipation 24 W
Encryption K9 encryption with limited VPN
Total number of ports 4
Wire size, alarm connection, solid or stranded, UL/CSA-rated style 1007 or 1569 twisted-pair copper appliance wiring material (AWM) wire 0.8 mm²
Wire size, DC power connection, solid or stranded copper wire rated at 75 °C or greater 0.8 mm²
Wire size, ethernet connection RJ45 connector according to IEC 60603-7, 2 or 4-pair category 5e minimum cable according to TIA 568-B.1 or category 5 cable according to ISO/IEC 24702
Wire size, ground connection, solid or stranded copper wire 4 mm²
Mounting method DIN rail (top hat rail)
Ethernet Yes
Protection type Alarm not rated
Wire insulation Copper
Insulation stripping length 6.3±0.5 mm
Alarm relay at 30V DC 1 A
Alarm relay at 48V DC 0.5 A
Current rating, user supply at 12 – 48V DC, maximum 2 A
Isolation voltage (continuous), basic insulation type, all ports to ground 60 V
Maximum insulation, DC power connection 1.2 mm
Number of ports 1GbE SFP 2
Wire strip length, alarm connection 6.3±0.5 mm
Wire strip length, DC power connection 6.3±0.5 mm
Wiring category on console ports 3
Wiring category on Ethernet ports 2
Wiring category on power and alarm ports 2

Environmental

Housing base material Open-style
Nominal position T4
Delta connected motor power, max T4
Temperature, surrounding air, maximum 60 °C
ESD immunity, IEC 61000-4-2, air discharges 8 kV
ESD immunity, IEC 61000-4-2, contact discharges 6 kV
Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 2000 – 2700 MHz 1 Kg/Km
Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 80 – 2000 MHz 10 Kg/Km
Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 900 MHz 10 Kg/Km
Shock, non-operating, IEC 60068-2-27 (test Ea, unpackaged shock) 30 g
Shock, operating, IEC 60068-2-27 (test Ea, unpackaged shock) 15 g
Temperature, operating, IEC 60068-2-1 (test Ad, operating, cold) -40 °C
Temperature, operating, IEC 60068-2-14 (test Nb, operating, thermal shock) -40 °C
Temperature, operating, IEC 60068-2-2 (test Bd, operating, dry heat) -40 °C
Emissions IEC 61000-6-4
Ambient temperature, maximum 60 °C
Conducted RF immunity, IEC 61000-4-6 with 1 kHz sine-wave 80% AM from 150 kHz – 80 MHz (rms) 10 V
Damped oscillatory wave immunity, IEC 61000-4-18, line-earth (CM) on communication ports ±500 V
Damped oscillatory wave immunity, IEC 61000-4-18, line-earth (CM) on power ports ±2.5 kV
Damped oscillatory wave immunity, IEC 61000-4-18, line-earth (CM) on signal ports ±1 kV
Damped oscillatory wave immunity, IEC 61000-4-18, line-line (DM) on power ports ±1 kV
Damped oscillatory wave immunity, IEC 61000-4-18, line-line (DM) on signal ports ±500 V
EFT/B immunity for IEC 61000-4-4 at 5 kHz on communication ports ±2 kV
EFT/B immunity for IEC 61000-4-4 at 5 kHz on power ports ±2 kV
EFT/B immunity for IEC 61000-4-4 at 5 kHz on signal ports ±2 kV
Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 1890 MHz 10 Kg/Km
Relative humidity, IEC 60068-2-30 (test Db, unpackaged damp heat), non-condensing 5 %
Surge transient immunity, IEC 61000-4-5, line-earth (CM) on communication ports ±2 kV
Surge transient immunity, IEC 61000-4-5, line-earth (CM) on power ports ±2 kV
Surge transient immunity, IEC 61000-4-5, line-earth (CM) on signal ports ±1 kV
Surge transient immunity, IEC 61000-4-5, line-line (DM) on power ports ±1 kV
Surge transient immunity, IEC 61000-4-5, line-line (DM) on signal ports ±500 V
Temperature, non-operating, IEC 60068-2-1 (test Ab, unpackaged non-operating cold) -40 °C
Temperature, non-operating, IEC 60068-2-14 (test Na, unpackaged non-operating thermal shock) -40 °C
Temperature, non-operating, IEC 60068-2-2 (test Bb, unpackaged non-operating dry heat) -40 °C
Vibration, IEC 60068-2-6 (test Fc, operating) at 5 – 150 Hz 1 g
Voltage variation IEC 61000-4-29, dips for 10 ms and 5 s on DC supply ports 100 %
Voltage variation IEC 61000-4-29, dips for 10 ms on DC supply ports 30 %
Voltage variation IEC 61000-4-29, dips for 100 ms and 1 s on DC supply ports 60 %
Peso 0.435 kg
Dimensiones 18.41 × 12.7 × 5.71 cm

Documentation

RESOURCE PUBLICATION NUMBER
Reference Manual ENET-RM002
User Manual 1783-UM007
Application Techniques ENET-AT007
Profile MIGRAT-PP043
Installation Instructions 1783-IN003
Technical Data 1783-TD002

Customers reviews

There are no reviews yet.

Be the first to review “1783-US6T2H, Stratix 2000 6T+2H Port Unmanaged Switch”

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

Search for products

Back to Top
Elegir Moneda
MXN Peso mexicano
Product has been added to your cart