Mechanical
Width | 106.68 cm |
---|---|
Height | 129.54 cm |
Depth | 159.26 cm |
Screw torque, alarm terminal | 0.56 Nm |
Screw torque, ground terminal | 0.4 Nm |
Screw torque, power terminal | 0.56 Nm |
Electrical
Number of ports 10/100/1000 Mbps RJ45 | 2 |
---|---|
Layer 2 | No |
Layer 3 | No |
Manageable | No |
Pulse (digital) output | 24 W |
Power dissipation | 24 W |
Encryption | K9 encryption with limited VPN |
Total number of ports | 4 |
Wire size, alarm connection, solid or stranded, UL/CSA-rated style 1007 or 1569 twisted-pair copper appliance wiring material (AWM) wire | 0.8 mm² |
Wire size, DC power connection, solid or stranded copper wire rated at 75 °C or greater | 0.8 mm² |
Wire size, ethernet connection | RJ45 connector according to IEC 60603-7, 2 or 4-pair category 5e minimum cable according to TIA 568-B.1 or category 5 cable according to ISO/IEC 24702 |
Wire size, ground connection, solid or stranded copper wire | 4 mm² |
Mounting method | DIN rail (top hat rail) |
Ethernet | Yes |
Protection type | Alarm not rated |
Wire insulation | Copper |
Insulation stripping length | 6.3±0.5 mm |
Alarm relay at 30V DC | 1 A |
Alarm relay at 48V DC | 0.5 A |
Current rating, user supply at 12 – 48V DC, maximum | 2 A |
Isolation voltage (continuous), basic insulation type, all ports to ground | 60 V |
Maximum insulation, DC power connection | 1.2 mm |
Number of ports 1GbE SFP | 2 |
Wire strip length, alarm connection | 6.3±0.5 mm |
Wire strip length, DC power connection | 6.3±0.5 mm |
Wiring category on console ports | 3 |
Wiring category on Ethernet ports | 2 |
Wiring category on power and alarm ports | 2 |
Environmental
Housing base material | Open-style |
---|---|
Nominal position | T4 |
Delta connected motor power, max | T4 |
Temperature, surrounding air, maximum | 60 °C |
ESD immunity, IEC 61000-4-2, air discharges | 8 kV |
ESD immunity, IEC 61000-4-2, contact discharges | 6 kV |
Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 2000 – 2700 MHz | 1 Kg/Km |
Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 80 – 2000 MHz | 10 Kg/Km |
Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 900 MHz | 10 Kg/Km |
Shock, non-operating, IEC 60068-2-27 (test Ea, unpackaged shock) | 30 g |
Shock, operating, IEC 60068-2-27 (test Ea, unpackaged shock) | 15 g |
Temperature, operating, IEC 60068-2-1 (test Ad, operating, cold) | -40 °C |
Temperature, operating, IEC 60068-2-14 (test Nb, operating, thermal shock) | -40 °C |
Temperature, operating, IEC 60068-2-2 (test Bd, operating, dry heat) | -40 °C |
Emissions | IEC 61000-6-4 |
Ambient temperature, maximum | 60 °C |
Conducted RF immunity, IEC 61000-4-6 with 1 kHz sine-wave 80% AM from 150 kHz – 80 MHz (rms) | 10 V |
Damped oscillatory wave immunity, IEC 61000-4-18, line-earth (CM) on communication ports | ±500 V |
Damped oscillatory wave immunity, IEC 61000-4-18, line-earth (CM) on power ports | ±2.5 kV |
Damped oscillatory wave immunity, IEC 61000-4-18, line-earth (CM) on signal ports | ±1 kV |
Damped oscillatory wave immunity, IEC 61000-4-18, line-line (DM) on power ports | ±1 kV |
Damped oscillatory wave immunity, IEC 61000-4-18, line-line (DM) on signal ports | ±500 V |
EFT/B immunity for IEC 61000-4-4 at 5 kHz on communication ports | ±2 kV |
EFT/B immunity for IEC 61000-4-4 at 5 kHz on power ports | ±2 kV |
EFT/B immunity for IEC 61000-4-4 at 5 kHz on signal ports | ±2 kV |
Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 1890 MHz | 10 Kg/Km |
Relative humidity, IEC 60068-2-30 (test Db, unpackaged damp heat), non-condensing | 5 % |
Surge transient immunity, IEC 61000-4-5, line-earth (CM) on communication ports | ±2 kV |
Surge transient immunity, IEC 61000-4-5, line-earth (CM) on power ports | ±2 kV |
Surge transient immunity, IEC 61000-4-5, line-earth (CM) on signal ports | ±1 kV |
Surge transient immunity, IEC 61000-4-5, line-line (DM) on power ports | ±1 kV |
Surge transient immunity, IEC 61000-4-5, line-line (DM) on signal ports | ±500 V |
Temperature, non-operating, IEC 60068-2-1 (test Ab, unpackaged non-operating cold) | -40 °C |
Temperature, non-operating, IEC 60068-2-14 (test Na, unpackaged non-operating thermal shock) | -40 °C |
Temperature, non-operating, IEC 60068-2-2 (test Bb, unpackaged non-operating dry heat) | -40 °C |
Vibration, IEC 60068-2-6 (test Fc, operating) at 5 – 150 Hz | 1 g |
Voltage variation IEC 61000-4-29, dips for 10 ms and 5 s on DC supply ports | 100 % |
Voltage variation IEC 61000-4-29, dips for 10 ms on DC supply ports | 30 % |
Voltage variation IEC 61000-4-29, dips for 100 ms and 1 s on DC supply ports | 60 % |
There are no reviews yet.