BMXART0814 analog isolated low level input module, Modicon X80, 8 inputs, 40mV positive or negative
MXN $24,200.86MXN $24,200.86 (sin impuestos)×
PGL36100U41A, Circuit breaker, PowerPacT P, 1000A, 3 pole, 600VAC, 18kA, lugs, Micrologic 3.0A, 80%
MXN $155,648.00 - (IVA Incluido) + Envío
PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn’t have that interchangeability. This circuit breaker has a Micrologic Interchangeable Ammeter with a 3.0A trip unit and an LI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has lugs on both the line and load sides. This PowerPacT P, 1000A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
Circuit breaker, PowerPacT P, 1000A, 3 pole, 600VAC, 18kA, lugs, Micrologic 3.0A, 80%
PGL36100U41A
Range | PowerPact |
---|---|
Product name | PowerPact P |
Product or Component Type | Circuit breaker |
Device Application | Distribution |
Line Rated Current | 1000 A |
---|---|
Number of Poles | 3P |
Control Type | Toggle |
Breaking capacity code | G |
Breaking capacity | AIR 65 kA 240 V AC 50/60 Hz UL 489 AIR 35 kA 480 V AC 50/60 Hz UL 489 AIR 18 kA 600 V AC 50/60 Hz UL 489 Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2 |
[Ue] rated operational voltage | 600 V AC 50/60 Hz UL 489 |
Network Frequency | 50/60 Hz |
[Ics] rated service breaking capacity | 25 kA 240 V AC 50/60 Hz IEC 60947-2 20 kA 380/415 V AC 50/60 Hz IEC 60947-2 |
[Uimp] rated impulse withstand voltage | 8 kV IEC 60947-2 |
Trip unit technology | Electronic, ammeter, MicroLogic 3.0 A, LI |
Continuous current rating | 80 % |
[Ui] rated insulation voltage | 750 V IEC 60947-2 |
Trip unit name | MicroLogic 3.0 A |
AWG gauge | 4 x AWG 3/0…500 kcmil aluminium/copper |
Local signalling | 1 trip indicator green) |
Electrical connection | Lugs, load Lugs, line |
Terminal identifier | AL1200P25K |
Long time pick-up adjustment range | 0.4…1 x Ir |
Tightening torque | 442.5 lbf.in (50 N.m) 0.1…0.4 in² (95…240 mm²) (4 x AWG 3/0…500 kcmil) 8.9…11.5 lbf.in (1.0…1.3 N.m) |
Number of slots | 2 auxiliary switch OF plug-in) 1 alarm switch SD plug-in) 1 overcurrent trip switch SDE plug-in) 1 voltage release MN or MX plug-in) |
Power wire stripping length | 1.2 in (30 mm) |
Height | 16.16 in (410.46 mm) |
Width | 8.27 in (210.06 mm) |
Depth | 8.05 in (204.47 mm) |
Net Weight | 32 lb(US) (14.5 kg) |
Quantity per Set | 1 |
Circuit breaker application | HACR rated |
Quality labels | CE |
---|---|
Standards | UL CSA NEMA NOM-003-SCFI-2000 IEC 60947-2 |
Product certifications | UL CSA NOM |
IP degree of protection | Front cover IP40 |
Pollution degree | 3 IEC 60947-1 |
Ambient Air Temperature for Operation | -13…158 °F (-25…70 °C) |
Ambient Air Temperature for Storage | -58…185 °F (-50…85 °C) |
Operating altitude | < 6561.68 ft (2000 m) without derating 13123.36 ft (4000 m) with derating |
Category | US10DE201215 |
---|---|
Discount Schedule | 0DE2 |
GTIN | 785901212843 |
Returnability | Yes |
Country of origin | US |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Warranty | 18 months |
---|
Peso | 5 kg |
---|---|
Dimensiones | 15 × 15 × 15 cm |
There are no reviews yet.