BMENOC0311 network module, Modicon M580, FactoryCast Ethernet
MXN $42,376.72MXN $42,376.72 (sin impuestos)× -
BMEP585040 standalone processor, Modicon M580, 24MB, 61 Ethernet devices, 31 remote IO racks of X80 and Quantum
MXN $277,630.17MXN $277,630.17 (sin impuestos)× -
BMXAMO0210 analog isolated high level output module, Modicon X80, 2 outputs, 0 to 20mA, 4 to 20mA, 10V positive or negative
MXN $11,761.21MXN $11,761.21 (sin impuestos)×
LRD332, TeSys Deca, thermal overload relay, 23 to 32 A, class 10A, EVERLINK
MXN $2,842.00 - (IVA Incluido) + Envío
27 disponibles
TeSys LRD overload relays are designed to be used with TeSys D contactors to make a motor starter. This overload relay can be used with 9 amp through 38 amp TeSys D contactors. These differential thermal overload relays detect over currents in the lines to the motor. When an overcurrent is detected the overload relay working with the contactor will disconnect the power to the motor. This will minimize the damage to the motor windings. This overload relay has an adjustable trip current rating of 16 to 24 amperes. This trip current rating is calibrated per Class 10A. This overload relay uses EVERLINK termnals in place of the standard terminals.
Marca:Schneider Electric
TeSys Deca, thermal overload relay, 23 to 32 A, class 10A, EVERLINK
LRD332
Range | TeSys TeSys Deca |
---|---|
Product name | TeSys LRD TeSys Deca |
Product or Component Type | Differential thermal overload relay |
Device short name | LRD |
relay application | Motor protection |
Product Compatibility | LC1D40A LC1D65A LC1D50A |
Network type | AC DC |
Thermal overload class | Class 10A IEC 60947-4-1 |
Thermal protection adjustment range | 23…32 A |
[Ui] rated insulation voltage | Power circuit 600 V CSA Power circuit 600 V UL Power circuit 690 V IEC 60947-4-1 |
Network Frequency | 0…400 Hz |
---|---|
Mounting support | Plate, with specific accessories Rail, with specific accessories Under contactor |
Tripping threshold | 1.14 +/- 0.06 Ir IEC 60947-4-1 |
Auxiliary contact composition | 1 NO + 1 NC |
[Ith] conventional free air thermal current | 5 A signalling circuit |
Permissible current | 0.95 A 380 V AC-15 signalling circuit 0.06 A 440 V DC-13 signalling circuit |
[Ue] rated operational voltage | 690 V AC 0…400 Hz power circuit IEC 60947-4-1 |
Associated fuse rating | 4 A gG for signalling circuit 4 A BS for signalling circuit |
[Uimp] rated impulse withstand voltage | 6 kV |
Phase failure sensitivity | Tripping current 130 % of Ir on two phase, the last one at 0 |
Control type | Red push-button stop Blue push-button reset |
Temperature compensation | -4.0000000000…140.0000000000 °F (-20…60 °C) |
Connections – terminals | Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) flexible without cable end Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) flexible with cable end Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) solid without cable end Power circuit EverLink BTR screw connectors 1 0.002…0.05 in² (1…35 mm²) flexible without cable end Power circuit EverLink BTR screw connectors 1 0.002…0.05 in² (1…35 mm²) flexible with cable end Power circuit EverLink BTR screw connectors 1 0.002…0.05 in² (1…35 mm²) solid without cable end |
Tightening torque | Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Power circuit 44.3 lbf.in (5 N.m) EverLink BTR screw connectors |
Height | 4.8 in (123 mm) |
Width | 2.2 in (55 mm) |
Depth | 4.8 in (123 mm) |
Net Weight | 0.827 lb(US) (0.375 kg) |
Climatic withstand | IACS E10 |
---|---|
IP degree of protection | IP20 conforming to IEC 60529 |
Ambient air temperature for operation | -4.0000000000…140.0000000000 °F (-20…60 °C) without derating IEC 60947-4-1 |
Ambient Air Temperature for Storage | -76.0000000000…158.0000000000 °F (-60…70 °C) |
Flame retardance | V1 conforming to UL 94 |
Mechanical robustness | Shocks15 Gn for 11 ms IEC 60068-2-7 Vibrations4 gn IEC 60068-2-6 |
Dielectric strength | 1.89 kV 50 Hz IEC 60947-1 |
Standards | EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-4-1 CSA C22.2 No 60947-5-1 GB/T 14048.4 GB/T 14048.5 EN 50495 |
Product Certifications | IEC UL CSA CCC EAC DNV-GL RMRS EU-RO MR LROS (Lloyds register of shipping) ATEX INERIS UKCA |
Category | US10I1222347 |
---|---|
Discount Schedule | 0I12 |
GTIN | 3389119215480 |
Returnability | Yes |
Country of origin | US |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 2.559 in (6.500 cm) |
Package 1 Width | 4.094 in (10.400 cm) |
Package 1 Length | 5.433 in (13.800 cm) |
Package 1 Weight | 13.862 oz (393.000 g) |
Unit Type of Package 2 | S02 |
Number of Units in Package 2 | 13 |
Package 2 Height | 5.906 in (15.000 cm) |
Package 2 Width | 11.811 in (30.000 cm) |
Package 2 Length | 15.748 in (40.000 cm) |
Package 2 Weight | 11.892 lb(US) (5.394 kg) |
Unit Type of Package 3 | P06 |
Number of Units in Package 3 | 208 |
Package 3 Height | 29.528 in (75.000 cm) |
Package 3 Width | 23.622 in (60.000 cm) |
Package 3 Length | 31.496 in (80.000 cm) |
Package 3 Weight | 207.270 lb(US) (94.016 kg) |
Warranty | 18 months |
---|
Peso | 0.391 kg |
---|---|
Dimensiones | 10.4 × 13.8 × 6.5 cm |
There are no reviews yet.