Motor Protection Circuit-Breaker

SKU: 140M-F8E-C45
Adj. Thermal Current Range (A) 32 – 45A,MxRtg MCPs(no OvPrt)is 1200.0A
Circuit Breaker Type Mtr Prt Circuit Breaker
With integrated auxiliary switch False
With integrated under voltage release False
Rated short-circuit breaking capacity lcu at 400 V, AC 65 kA
Rated operation power at AC-3, 400 V 22 kw
Rated permanent current Iu 45 A
Rated operation power at AC-3, 230 V 13 kw
Rated operating voltage 230 A
Type of control element Turn button
Overload release current setting 32 A
Type of electrical connection of main circuit Screw connection
Magnetic release current per IEC 585 A
Magnetic trip current, nom 585 A
Rated operational current (Ie) per IEC 45 A
Rated supply current (Ie) 6.3 A
Short circuit current (Icu) for group motor installation, max 65kA @ 480V
Short circuit current (Type 2 coordination) with 100-C IEC contactor, max 65kA @ 480V
Current range 32…45 A
Ultimate short circuit breaking capacity (Icu) per IEC 65kA @ 400/415V AC
Rated service short circuit breaking capacity (Ics) per IEC 6kA @ 690V AC
Insulation voltage (Ui) Rated 690V per IEC
Hp rating, max 40Hp @ 575V, 3-phase
Electrical life cycle 30000 ops (Ie maximum)
Short circuit current for self-protected combination motor controller with 100-C contactor, max 65 kA @ 480Y/277V, UL 508-Type E
Switching of standard motors per IEC 40 kW @ 690V (AC-3), 3-phase
KW rating, max 40 kW @ 690V (AC-3), 3-phase
Back up fuse (gG, gL) current rating (if Icc ≥ Icu ) per IEC No back-up fuse required @ 230/240V AC
Short circuit current for combination motor controller with 100-C IEC contactor, max 65 kA @ 480Y/277V, UL 60947-4-1-Type F
Total power loss (Pv) for circuit breaker 7…22 W @ rated load/operating temperature
Short circuit current for group motor installation with 100-C IEC contactor, max 65kA @ 480V, UL 60947-4-1-manual motor controller
Short circuit current for motor disconnect with 100-C IEC contactor, max 65kA @ 480V, UL 60947-4-1-manual motor controller
Rated thermal current (Ith) 6.3…45 A up to 60 °C (140 °F) ambient temperature
Short circuit current for tap conductor protection, max 65 kA @ 480Y/277V, UL 60947-4-1-manual motor controller
Short circuit current for combination motor controller, max 65kA @ 480V/277V, UL 60947-4-1 self-protected (Type E)
Fuse or circuit breaker per NEC, max 600 A, UL 60947-4-1-manual motor controller
Rated impulse withstand voltage (Uimp) Main circuits (Uimp)/overvoltage category: 6 kV/III, 8 kV (disconnect)
Short circuit current for group motor installation, max 65kA @ 480V, UL 60947-4-1-manual motor controller
Short circuit current for motor disconnect, max 65kA @ 480V, UL 60947-4-1-manual motor controller
Number of poles 3
With thermal protection True
Phase failure sensitive True
Switch off technique Thermomagnetic
Switching frequency, max 25 ops/h
Trip class 10
Rated frequency 45 Hz
Phase loss protection Differential release
Fuse or circuit breaker rating with 100-C IEC contactor per NEC, max 600 A, UL 60947-4-1-manual motor controller
Width 54 mm
Depth 110 mm
Height 111.4 mm
Contactor size (Type 2 coordination) with 100-C IEC contactor, min 100-C37 @ 600V
Frame size Frame size F, 45 A
Contactor size, min 100-C37, UL-508 -Type E self-protected combination motor controller
Device construction Built-in device fixed built-in technique
Degree of protection (IP) IP2X
Weight 782 lb
Mechanical life operations 30000 /h
Breaking capacity High breaking capacity
Shock Transport (60068-2-27): 30 G/11 ms, OFF
Protection type Adjustable thermal/fixed magnetic (13 x In)
Factory option No circuit-breaker auxiliary or trip contacts
Vibration Ops (60068-2-6): 5 G
Ambient storage temperature -40 °C
Ambient operating temperature -25 °C
Ambient temperature compensation -25 °C
Site altitude To 2000 m N.N. (6561 ft)
Dependence on temperature No reduction @ 60 °C (140 °F)
Magnetic release current (±20 %) Fixed setting: 18…22 x Ie maximum (Ie maximum = maximum values of setting ranges) for T version
Pollution degree 3
Climatic resistance Operating humidity/moisture heat (60068-2-3): 5…95% non-condensing
Utilization category Motor starter: AC-3 (IEC60947-4-1)
Overload protection characteristics IEC 60947-4-1 motor protection
Peso 0.835 kg
Dimensiones 12.49 × 12.29 × 6.19 cm
Type Resource Publication
General Product Cutsheet --
General Short Circuit Ratings Data Sheet --
Technical Data 140m-td002_-en-p 140M-TD002
,
Product Cutsheet General
--
Short Circuit Ratings Data Sheet General
--
140m-td002_-en-p Technical Data
140M-TD002
,

Customers reviews

There are no reviews yet.

Be the first to review “140M-F8E-C45, Motor Protection Circuit-Breaker”

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

Trade Mark & Brands

Llámanos 24/7 +52 55 61 22 77 00

Omega Automation México

Email: ventas@omegaautomation.com.mx

© Omega Automation. Todos los Derechos Reservados.

Omega Automation se dedica a suministrar productos de automatización e industriales confiables, respaldados por un servicio al cliente de alta calidad. Los productos ofrecidos en este sitio son adquiridos a través de distribuidores oficiales autorizados. Sin embargo, Omega Automation no actúa como distribuidor oficial autorizado ni como representante de los fabricantes mencionados en este sitio web. Este sitio web no cuenta con el respaldo ni la aprobación de ningún fabricante o marca comercial mencionada. Todas las marcas registradas, nombres comerciales y logotipos presentes en este sitio son propiedad de sus respectivos propietarios.

Search for products

Back to Top
Elegir Moneda
MXN Peso mexicano
Product has been added to your cart