100-E09KN10, IEC 9 A Contactor

MXN $3,294.50 - (IVA Incluido) + Envío

11 disponibles

IEC 9 A Contactor

Buy it now
SKU: 100-E09KN10
Number of auxiliary contacts as normally open contact 1
Number of auxiliary contacts as normally closed contact 0
Vibration resistance IEC 60068-2-6
Shock resistance IEC 60068-2-27
Altitude, max 3000 m of installation site
Switching frequency, max 600 ops/hr, AC-1
Weight AC/DC (electronic): 0.43 kg (0.95 lbs.)
Protection class Contactor main contact: IP2X
Voltage type for actuating AC/DC
Rated control supply voltage at AC 50 Hz 250 V
Rated control supply voltage at AC 60 Hz 250 V
Rated control supply voltage at DC 250 V
Type of electrical connection of main circuit Screw connection
Rated impulse voltage withstand (Uimp) 6 kV
Operating time, closing delay 40 ms
Optional overload relays Electronic
Main current circuit resistance 0.41 mΩ
Rated isolation voltage (Ui) 690V per IEC
Function Non-reversing contactor
Standard coil, pick-up 50VA/50 W @ 250…500V AC/DC
Standard coil, hold-in 2.2VA/2 W @ 250…500V AC/DC
General purpose current (enclosed) 13.8A @ 600V per UL/CSA
Power dissipation 0.8 W per pole at Ie, AC-1, 400V
Short time withstand (Icw) 3-pole: 80A @ 30s (40 °C)
FLA 20A @ 600V, 3-phase per UL/CSA HVAC applications
Rated operational current and power (enclosed) 9.5A @ 125V DC, with 3-poles in series per UL/CSA
LRA 80 A @ 550-600V, 3-phase AC per UL/CSA HVAC applications
Electromagnetic compatibility IEC 60947-1 – Environment A and B (100-E09…E38 only)
Total power dissipation 2.3 W at Ie, AC-3, 400V, AC/DC control (120-250V)
Operating limits, dropout (≤0.60) x Us @ DC control
Rating for switching AC motors 3-poles: 7.5Hp @ 575V, AC-2, AC-3 (60 Hz)
Operating limits, pick-up (0.85…1.1) x Us @ 50/60 Hz
MCCB current rating Type 2 (per IEC 60947-4-1): 28A @ 400V, 70 kA available fault current
DIN fuses (gG) current rating Type 2 (per IEC 60947-4-1): 6A @ 690V, 60 kA available fault current
Rated voltage (Ue) 24, 48, 110, 220, 440V DC
Rated operational current and power 5.8A @ 115V AC, 500000 electrical ops, 1-phase per UL/CSA elevator duty
Coil voltage 250 to 500V AC/DC
Switching of lighting loads Tungsten lA: 20A @ 600V, 3-phase (break all lines) per UL/CSA
UL class RK5 fuses rating Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 30A @ 600V, 5 kA available fault current
Rated operational current (Ie) 9.5A @ 500V, Star-Delta starting (50 Hz)
UL class J and CSA HRCI-J fuses rating Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 30A @ 600V, 100 kA available fault current
UL inverse-time circuit breaker Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 60A @ 600V, 5 kA available fault current
Switching of power transformers Apparent power: 8 kVA @ 415V, AC-6a @ 50Hz (n = 30)
Rated operational power (Pe) 9 kW @ 240V, AC-1 active power load (50/60 Hz), ambient temperature 70 °C (158 °F)
Switching of DC loads 3-poles in series: 9A @ 220V (Series-wound motors-starting, reverse current breaking, reversing, stepping: DC-5 at 60 °C)
Optional accessories Side-or front-mount auxiliary contacts, Mechanical interlocks, Connecting bars
Features Panel mounting or mounting on 35 mm DIN rail, AC/DC electronic coil, Made of environmentally friendly materials
Climatic withstand Category B according to IEC 60947-1, annex Q
Ambient temperature Storage: -60 °C…80 °C (-76 °F…176 °F)
Coil insulation class Class F per IEC 60947-4-1
Peso 0.32 kg
Dimensiones 7.87 × 8.63 × 4.57 cm
Type Resource Publication
General Product Cutsheet --
Technical Data 100-td013_-en-p 100-TD013
,
Product Cutsheet General
--
100-td013_-en-p Technical Data
100-TD013
,

Customers reviews

There are no reviews yet.

Be the first to review “100-E09KN10, IEC 9 A Contactor”

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

Search for products

Back to Top
Elegir Moneda
MXN Peso mexicano
Product has been added to your cart