Programmable receiver – 2 relays – 24..240 V AC/DC – 2 pusbuttons – 6 LEDs
ZBRRA
Range of Product | Harmony |
---|---|
Product or Component Type | Programmable receiver |
Device short name | ZBRRA |
Product Specific Application | Interface to actuators |
Function of module | Bi-stable Monostable Stop/start |
Reset time | 2 ms time delay |
Transmission frequency | 2405 MHz |
emission class | 5M00G7W |
Antenna type | Omnidirectional |
Nominal output current | 0.3 A 48 V DC IEC 60947-5-1 3 A 24 V DC UL 508 1.5 A 240 V AC IEC 60947-5-1 3 A 120 V AC IEC 60947-5-1 3 A 240 V AC UL 508 3 A 24 V DC CSA C22.2 No 14 3 A 240 V AC CSA C22.2 No 14 |
---|---|
Output Type | 2 relays |
Output contacts | 2 C/O |
Input output isolation | Galvanic isolation |
Time delay range | 0.5 s – 15…15 %) |
Switching capacity in VA | 1250 VA |
Maximum switching current | 5 mA AC/DC |
Maximum switching voltage | 250 V AC/DC |
[Us] Rated Supply Voltage | 24…240 V AC/DC 50/60 Hz – 10…10 % |
Communication port protocol | Zigbee green power 2.4 GHz IEEE 802.15.4 |
Maximum sensing distance | 328.08 ft (100 m) in free field 82.02 ft (25 m) transmitter in a plastic box type XAL D and receiver in a metal enclosure 131.2 ft (40 m) transmitter in box type XAL D, receiver in metal enclosure and use relay-antenna |
Response Time | < 30 ms after transmitter clicks |
Utilisation category | AC-15 : B300 IEC 60947-5-1 DC-12 IEC 60947-5-1 |
Maximum power consumption in W | 4 W AC/DC |
Breaking capacity | 15 W |
Breaking capacity | 750 VA |
Control circuit frequency | 50…60 Hz +/- 10 % |
Short-circuit protection | 0.4 A fuse fast blow |
Operating position | Any position without derating |
Electrical connection | 1 conductor cable 0.0002…0.004 in² (0.14…2.5 mm²) – AWG 26…AWG 14 – solid – without cable end IEC 60947-1 2 conductors cable 0.0002…0.002 in² (0.14…1.5 mm²) – AWG 26…AWG 16 – solid – without cable end IEC 60947-1 1 conductor cable 0.0002…0.006 in² (0.14…4 mm²) – AWG 26…AWG 12 – flexible – with cable end IEC 60947-1 2 conductors cable 0.0002…0.002 in² (0.14…1.5 mm²) – AWG 26…AWG 16 – flexible – with cable end IEC 60947-1 |
Tightening torque | 4.4…8.9 lbf.in (0.5…1 N.m) IEC 60947-1 |
Housing material | Self-extinguishing plastic |
Status LED | 1 LED Green power ON 2 LEDs Green relay ON 2 LEDs Green function mode 1 LED green and yellow reception signal |
Mounting support | 35 mm symmetrical DIN rail conforming to IEC 60715 Mounting plate |
Rated short-duration power frequency withstand voltage | 1.5 kV 50 Hz IEC 60947-5-1 |
[Uimp] rated impulse withstand voltage | 4 kV |
Surge withstand | 1 kV differential mode IEC 61000-4-5 2 kV common mode IEC 61000-4-5 |
Max power consumption in W | 1 mW |
Number of channels | 1 |
modulation technique | O-QPSK |
Bandwidth | 5 MHz |
Antenna gain | 0 dBi |
Width | 1.4 in (36 mm) |
Height | 4.3 in (108 mm) |
Depth | 3.0 in (75 mm) |
Net Weight | 0.29 lb(US) (0.13 kg) |
Standards | CSA C22.2 No 14 UL 508 IEC 60947-5-1 IEC 60947-1 |
---|---|
Radio agreement | RSS SRRC ANATEL ARIB T66 FCC ICASA |
Product Certifications | C-tick CCC CSA UL GOST |
marking | CE |
Ambient Air Temperature for Storage | -40.0000000000…158.0000000000 °F (-40…70 °C) |
Relative humidity | 90 % -4.0000000000…131.0000000000 °F (-20…55 °C), without condensation ETSI EN 300 440-1 |
Vibration resistance | +/- 7.5 mm 5…14 Hz)IEC 60068-2-6 2 gn 8…150 Hz)IEC 60068-2-6 |
Shock resistance | 10 gn 16 ms) 6000 shocks IEC 60068-2-27 |
IP degree of protection | IP20 IEC 60529 casing) IP20 terminals) |
Pollution degree | 2 IEC 60664-1 |
Overvoltage category | II IEC 60664-1 |
Insulation resistance | > 500 MOhm 500 V DC NF C 20-030 |
[Ui] rated insulation voltage | 250 V IEC 60664-1 |
Electromagnetic compatibility | Immunity for industrial environments conforming to IEC 61000-6-2 Conducted and radiated emissions class B conforming to CISPR 22 Electrostatic discharge immunity test – test level: 8 kV (in free air (in insulating parts)) conforming to IEC 61000-4-2 Electrostatic discharge immunity test – test level: 6 kV (on contact (on metal parts)) conforming to IEC 61000-4-2 Susceptibility to electromagnetic fields – test level: 10 V/m (80…2000 MHz) conforming to IEC 61000-4-3 Susceptibility to electromagnetic fields – test level: 3 V/m (80…2700 MHz, distance = 20 m) conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test – test level: 2 kV (relay wires) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test – test level: 2 kV (power supply wires) conforming to IEC 61000-4-4 1.2/50 µs shock waves immunity test – test level: 1 kV (differential mode) conforming to IEC 61000-4-5 1.2/50 µs shock waves immunity test – test level: 2 kV (common mode) conforming to IEC 61000-4-5 Conducted RF disturbances – test level: 10 V conforming to IEC 61000-4-6 Immunity to microbreaks and voltage drops – test level: 10 ms conforming to IEC 61000-4-11 Radiated emission conforming to ETSI EN 300 440-1 Conducted emission conforming to EN 300-489-1 Conducted emission conforming to ETSI EN 300 489-3 Radiated emission conforming to ETSI EN 300 440-2 |
Electrical durability | 100000 cycles |
Mechanical durability | 1000000 cycles |
Category | US1000I22470 |
---|---|
Discount Schedule | 000I |
GTIN | 3606480334702 |
Returnability | Yes |
Country of origin | US |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 1.8 in (4.6 cm) |
Package 1 Width | 3.1 in (8 cm) |
Package 1 Length | 3.8 in (9.6 cm) |
Package 1 Weight | 4.9 oz (138 g) |
Unit Type of Package 2 | S03 |
Number of Units in Package 2 | 64 |
Package 2 Height | 11.8 in (30 cm) |
Package 2 Width | 11.8 in (30 cm) |
Package 2 Length | 15.7 in (40 cm) |
Package 2 Weight | 20.898 lb(US) (9.479 kg) |
Warranty | 18 months |
---|