LRD02 is a TeSys LRD thermal overload relay from Schneider Electric to be used with a TeSys D contactor. It protects motors 0.06kW@400V thanks to a thermal range 0.16-0.25A, a tripping class 10A and phase unbalance protection. LRD02 is a TeSys LRD thermal overload relay from Schneider Electric for direct mounting on TeSys D contactors. With a thermal setting range 0.16-0.25A, a tripping class 10A and phase unbalance detection, it protects motors 0.06kW@400V. It provides manual test & reset buttons, automatic reset, trip auxiliary contact and flag indicator. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Thermal overload protection relay, bimetallic type, with phase unbalance protection (differential). Direct mounting on the bottom terminals of a Tesys contactor LC1D09-D38 to form a compact starter. Light and compact, 45mm wide. Temperature compensated for a good accuracy of the protection. Manual control with test & reset buttons, manual / automatic reset selector. Trip signaling with 1NO+1NC auxiliary contacts and trip flag indicator. Can be completed with terminal blocks for separate mounting (LAD7B, LAD96) and remote control devices (LAD703, LA7D03).

Buy it now
Brands:
SKU: LRD02

TeSys Deca thermal overload relays – 0.16…0.25 A – class 10A

LRD02

Main
Range TeSys
TeSys Deca
Product name TeSys LRD
TeSys Deca
Product or Component Type Differential thermal overload relay
Device short name LRD
relay application Motor protection
Product Compatibility LC1D25
LC1D38
LC1D12
LC1D09
LC1D18
LC1D32
Network type DC
AC
Thermal overload class Class 10A IEC 60947-4-1
Thermal protection adjustment range 0.16…0.25 A
[Ui] rated insulation voltage Power circuit 600 V CSA
Power circuit 600 V UL
Power circuit 690 V IEC 60947-4-1
Complementary
Network Frequency 0…400 Hz
Mounting support Plate, with specific accessories
Rail, with specific accessories
Under contactor
Tripping threshold 1.14 +/- 0.06 Ir IEC 60947-4-1
Auxiliary contact composition 1 NO + 1 NC
[Ith] conventional free air thermal current 5 A signalling circuit
Permissible current 3 A 120 V AC-15 signalling circuit
0.22 A 125 V DC-13 signalling circuit
[Ue] rated operational voltage 690 V AC 0…400 Hz power circuit IEC 60947-4-1
Associated fuse rating 4 A gG for signalling circuit
4 A BS for signalling circuit
[Uimp] rated impulse withstand voltage 6 kV
Phase failure sensitivity Tripping current 130 % of Ir on two phase, the last one at 0
Control type Red push-button stop
Blue push-button reset
Temperature compensation -4.0000000000…140.0000000000 °F (-20…60 °C)
Connections – terminals Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) flexible without cable end
Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) flexible with cable end
Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) solid without cable end
Power circuit screw clamp terminals 1 0.002…0.02 in² (1.5…10 mm²) flexible without cable end
Power circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) flexible with cable end
Power circuit screw clamp terminals 1 0.002…0.009 in² (1…6 mm²) solid without cable end
Tightening torque Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals
Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals
Height 2.6 in (66 mm)
Width 1.8 in (45 mm)
Depth 2.8 in (70 mm)
Net Weight 0.273 lb(US) (0.124 kg)
Environment
Climatic withstand IACS E10
IP degree of protection IP20 conforming to IEC 60529
Ambient air temperature for operation -4.0000000000…140.0000000000 °F (-20…60 °C) without derating IEC 60947-4-1
Ambient Air Temperature for Storage -76.0000000000…158.0000000000 °F (-60…70 °C)
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations6 Gn IEC 60068-2-6
Shocks15 Gn for 11 ms IEC 60068-2-7
Dielectric strength 1.89 kV 50 Hz IEC 60947-1
Standards EN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
UL 60947-5-1
CSA C22.2 No 60947-4-1
CSA C22.2 No 60947-5-1
GB/T 14048.4
GB/T 14048.5
EN 50495
Product Certifications IEC
UL
CSA
CCC
EAC
BV
RINA
DNV-GL
LROS (Lloyds register of shipping)
ATEX INERIS
UKCA
Ordering and shipping details
Category US10I1222347
Discount Schedule 0I12
GTIN 3389110346725
Returnability Yes
Country of origin MX
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 1.969 in (5.000 cm)
Package 1 Width 3.150 in (8.000 cm)
Package 1 Length 3.543 in (9.000 cm)
Package 1 Weight 4.797 oz (136.000 g)
Unit Type of Package 2 S02
Number of Units in Package 2 24
Package 2 Height 5.906 in (15.000 cm)
Package 2 Width 11.811 in (30.000 cm)
Package 2 Length 15.748 in (40.000 cm)
Package 2 Weight 7.884 lb(US) (3.576 kg)
Unit Type of Package 3 P06
Number of Units in Package 3 384
Package 3 Height 29.528 in (75.000 cm)
Package 3 Width 23.622 in (60.000 cm)
Package 3 Length 31.496 in (80.000 cm)
Package 3 Weight 144.024 lb(US) (65.328 kg)
Contractual warranty
Warranty 18 months
Peso 0.137 kg
Dimensiones 8 × 9 × 5 cm
Product Datasheet
User guide
Instruction Sheet
Catalog
Environmental Disclosure

Customers reviews

There are no reviews yet.

Be the first to review “LRD02, TeSys Deca thermal overload relays – 0.16…0.25 A – class 10A”

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

Search for products

Back to Top
Elegir Moneda
MXN Peso mexicano
Product has been added to your cart