Necesitas Ayuda?+52 55 61 22 77 00
Correo: ventas@omegaautomation.com.mx

ATS480C32Y, Soft starter, Altistart 480, 320A, 208 to 690V AC, control supply 110 to 230V AC

MXN $157,747.00 - (IVA Incluido) + Envío

9 disponibles

Altivar Soft Starter ATS480 is intended to start and stop asynchronous motors supplied from 208V to 690V. It meets the requirements of the most demanding applications in normal and heavy duty. With an operational rated current of 320A in normal duty, it supplies motor from 90kW to 315kW according to mains voltage. Designed for digitization, connected, optimized to meet cybersecurity standard, it simplifies project execution and maximizes the availability of applications. Its torque control (TCS) masters acceleration and deceleration. It efficiently stops high inertia application thanks to the dynamic braking and DC injection. It could be connected in-line or inside the delta to reduce its operational current. The embedded test routine simplifies the commissioning inside the delta. Its dimensions are 320mm (width) x 277mm (depth) x 380mm (height) and it weighs 18,2kg. Altivar Soft Starter ATS480 is designed to address process, infrastructures and industrial machines. It conforms to IEC/EN60947-4-1. It is certified CE, cULus, UKCA, CCC, RCM, EAC, and Marine certified DNV, ABS, BV and CCS. Display terminals, remote mounting kit, communication modules are common with Altivar Drives. Line chokes, DNV kits are common with ATS48. ATS480 is compatible with ATS48, it has same footprint, fixing, torque control algorithm, I/O, menus… The integration of Altivar Soft Starter ATS480 in EcoStruxure drastically simplifies architecture selection, detailed design and execution in automation and electrical systems. It is a Green Premium product designed to take the environmental considerations beyond current directives and regulations, compliant with RoHS and REACH.

Buy it now
SKU: ATS480C32Y

Soft starter, Altistart 480, 320A, 208 to 690V AC, control supply 110 to 230V AC

ATS480C32Y

Main
Range of Product Altivar Soft Starter ATS480
Product or Component Type Soft starter
product destination Asynchronous motors
Product Specific Application Process and infrastructures
Device short name ATS480
Phase 3 phase
Utilisation category AC-3A
AC-53A
Ue power supply voltage 208…690 V – 15…10 %
power supply frequency 50…60 Hz – 20…20 %
[Ie] rated operational current Normal duty 320.0 A 104.0000000000 °F (40 °C))
rated current in heavy duty 250.0 A at 104.0000000000 °F (40 °C) heavy duty
Torque control True
IP Degree of Protection IP00
Motor power kW 90.0 kW 230 V in the motor supply line normal duty
75.0 kW 230 V in the motor supply line heavy duty
160.0 kW 400 V in the motor supply line normal duty
132.0 kW 400 V in the motor supply line heavy duty
160.0 kW 440 V in the motor supply line normal duty
132.0 kW 440 V in the motor supply line heavy duty
220.0 kW 500 V in the motor supply line normal duty
160.0 kW 500 V in the motor supply line heavy duty
220.0 kW 525 V in the motor supply line normal duty
160.0 kW 525 V in the motor supply line heavy duty
250.0 kW 660 V in the motor supply line normal duty
220.0 kW 660 V in the motor supply line heavy duty
315.0 kW 690 V in the motor supply line normal duty
250.0 kW 690 V in the motor supply line heavy duty
160.0 kW 230 V to the motor delta terminals normal duty
132.0 kW 230 V to the motor delta terminals heavy duty
250.0 kW 400 V to the motor delta terminals normal duty
220.0 kW 400 V to the motor delta terminals heavy duty
Maximum Horse Power Rating 100.0 hp 208 V normal duty
75.0 hp 208 V heavy duty
125.0 hp 230 V normal duty
100.0 hp 230 V heavy duty
250.0 hp 460 V normal duty
200.0 hp 460 V heavy duty
300.0 hp 575 V normal duty
250.0 hp 575 V heavy duty
Option card Communication module Profibus DP V1
Communication module PROFINET
Communication module Modbus TCP/EtherNet/IP
Communication module CANopen daisy chain
Communication module CANopen Sub-D
Communication module CANopen open style
Complementary
Device connection In the motor supply line
To the motor delta terminals
[Us] control circuit voltage 110…230 V AC 50/60 Hz – 15…10 %
Apparent power 0.106 kVA
Integrated motor overload protection True
motor thermal protection class Class 10E
Protection type Phase failure line
Integrated thermal protection motor
Thermal protection starter
Current overload motor
Underload motor
Excessive starting time, locked rotor motor
Motor phase loss motor
Line supply phase loss line
Line supply phase loss motor
Thermal protection motor
current limiting %In (5 x Ie maximum) 150…700 %
[In] Rated current pwr loss specifctn 320.0 A
Power loss static current independent 25.0 W
Power loss per device current dependent 882.0 W
Standards IEC 60947-4-2
UL 60947-4-2
IEC 60664-1
Product Certifications CE
cULus
CCC
UKCA
RCM
EAC
DNV
ABS
BV
CCS
marking CE
CCC
UKCA
EAC
RCM
CULus
[Uc] control circuit voltage 24 V DC
Discrete input number 4
Discrete input type STOP) logic inputs, 3500 Ohm
RUN) logic inputs, 3500 Ohm
DI3) programmable as logic input, 3500 Ohm
DI4) programmable as logic input, 3500 Ohm
Input compatibility STOP discrete input level 1 PLC IEC 61131-2
RUN discrete input level 1 PLC IEC 61131-2
DI3 discrete input level 1 PLC IEC 61131-2
DI4 discrete input level 1 PLC IEC 61131-2
Discrete input logic Programmable digital input < 5 V
Relay output number 3
Relay output type Relay outputs R1A 1 NO
Relay outputs R1B 1 NO
Relay outputs RIC NO/NC programmable
Minimum switching current 100 mA 12 V DC relay outputs
Maximum switching current Relay outputs 2 A 250 V AC
Relay outputs 2 A 30 V DC
Relay outputs
Discrete output number 2
Discrete output type DQ1) programmable digital output <= 30 V
DQ2) programmable digital output <= 30 V
Output compatibility Open collector level 1 PLC IEC 65A-68
Analogue input number 1
Analogue input type AI1/PTC PTC/Pt 100 temperature probe
PTC2 PTC/Pt 100 temperature probe
PTC3 PTC/Pt 100 temperature probe
Analogue output number 1
Analogue output type Current output AQ1 0…20 mA or 0…10 V 500 Ohm
Communication Port Protocol Modbus serial
Connector Type 1 RJ45
Communication data link Serial
Physical interface 2-wire RS 485
Transmission Rate 1200…256000 bit/s
Transmission frame RTU
Data format 8 bits, configurable odd, even or no parity
Type of polarization No impedance Modbus serial
Number of addresses 0…227 Modbus serial
Method of access Slave Modbus serial
Function Available External bypass control
Pre-heating
Smoke extraction
Multi-motor cascade
Second motor set
User management
Ports and services hardening
Security event logging
Cybersecure firmware update
Single direction
Display screen available True
Operating position Vertical +/- 10 degree
Height 15.0 in (380.0 mm)
Width 12.6 in (320.0 mm)
Depth 10.9 in (277.0 mm)
Net Weight 40.1 lb(US) (18.2 kg)
Environment
Electromagnetic compatibility Conducted and radiated emissions level A IEC 60947-4-2
Conducted and radiated emissions with bypass level B IEC 60947-4-2
Damped oscillating waves level 3 IEC 61000-4-12
Electrostatic discharge level 3 IEC 61000-4-11
Immunity to electrical transients level 4 IEC 61000-4-4
Immunity to radiated radio-electrical interference level 3 IEC 61000-4-3
Voltage/current impulse level 3 IEC 61000-4-5
Pollution degree Level 3
[Uimp] rated impulse withstand voltage 6 kV
[Ui] Rated Insulation Voltage 690 V
Environmental class (during operation) Class 3C3 according to IEC 60721-3-3
Class 3S2 according to IEC 60721-3-3
Relative humidity 0…95 % without condensation or dripping water IEC 60068-2-3
Ambient air temperature for operation 104.0000000000…140.0000000000 °F (40…60 °C) with current derating of 2 % per °C)
5.0000000000…104.0000000000 °F (-15…40 °C) without derating)
Ambient Air Temperature for Storage -13.0000000000…158.0000000000 °F (-25…70 °C)
Operating altitude <= 3280.84 ft (1000 m) without derating
> 3280.84…13123.36 ft (> 1000…4000 m) with current derating 1 % per 100 m
Maximum deflection under vibratory load (during operation) 1.5 mm at 2…13 Hz
Maximum deflection under vibratory load (during storage) 1.75 mm at 2…9 Hz
Maximum deflection under vibratory load (during transport) 1.75 mm at 2…9 Hz
Maximum acceleration under vibrational stress (during operation) 10 m/s² at 13…200 Hz
Maximum acceleration under vibratory load (during storage) 15 m/s² at 200…500 Hz
10 m/s² at 9…200 Hz
Maximum acceleration under vibratory load (during transport) 15 m/s² at 200…500 Hz
10 m/s² at 9…200 Hz
Maximum acceleration under shock impact (during operation) 150 m/s² at 11 ms
Maximum acceleration under shock load (during storage) 100 m/s² at 11 ms
Maximum acceleration under shock load (during transport) 100 m/s² at 11 ms
Ordering and shipping details
Category US1CP1G22588
Discount Schedule CP1G
GTIN 3606481089120
Returnability Yes
Country of origin ID
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 19.685 in (50.000 cm)
Package 1 Width 15.748 in (40.000 cm)
Package 1 Length 23.622 in (60.000 cm)
Package 1 Weight 58.423 lb(US) (26.500 kg)
Peso 26.5 kg
Dimensiones 40 × 60 × 50 cm
Product Datasheet
User guide
Instruction Sheet
Catalog
Environmental Disclosure

Customers reviews

There are no reviews yet.

Be the first to review “ATS480C32Y, Soft starter, Altistart 480, 320A, 208 to 690V AC, control supply 110 to 230V AC”

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

Search for products

Back to Top
Elegir Moneda
MXN Peso mexicano
Product has been added to your cart