Technical Specifications
Electrical
With optical interface | No |
---|---|
Supporting protocol for TCP/IP | No |
Supporting protocol for DeviceNet | No |
Supporting protocol for other bus systems | No |
Redundancy | No |
IO link master | No |
Supporting protocol for DeviceNet Safety | No |
Supporting protocol for EtherNet/IP | Yes |
Type of data transmission | Module rack extension |
Thermal dissipation, max | 9.6 BTU/h |
Power dissipation, max | 2.8 W |
Wire category | 2 – power ports, 2 – communication ports |
Module keying | None |
Isolation voltage | 250V (continuous), basic insulation type, SA and MOD power to backplane, 250V (continuous), basic insulation type, backplane to communication channels, 250V (continuous), basic insulation type, backplane to chassis ground, 250V (continuous), basic insulat |
Supporting protocol for LON | No |
Supporting protocol for ASI | No |
Supporting protocol for PROFIBUS | No |
Supporting protocol for CAN | No |
Supporting protocol for INTERBUS | No |
Supporting protocol for KNX | No |
Supporting protocol for Modbus | No |
Supporting protocol for Data-Highway | No |
Supporting protocol for SUCONET | No |
With potential separation | No |
Supporting protocol for SERCOS | No |
Supporting protocol for INTERBUS-Safety | No |
Supporting protocol for AS-Interface Safety at Work | No |
Supporting protocol for Foundation Fieldbus | No |
Supporting protocol for PROFINET CBA | No |
Supporting protocol for PROFINET IO | No |
Supporting protocol for PROFIsafe | No |
Supporting protocol for SafetyBUS p | No |
Slot width | 1 |
ATEX temp code | T4 |
RTB keying | None |
Transmit transaction ID | 0…255 |
Serial port connectors | Two DB-9 male with pins |
Operating mode | Generic ASCII, Modbus RTU, Modbus ASCII |
Inputs | 2 full-duplex (RS-232, RS-422), 2 half-duplex (RS-485) |
Handshaking | RTS/CTS hardware handshake always enabled, RTS/CTS can be controlled by the user |
Indicators | 1 green/red module status indicator, 1 transmit data (TXD) and 1 receive data (RXD) yellow/red status indicator per channel |
Serial input voltage signal | 3…25V DC regarding signal ground (SG) 0, asserted, ON, space, active, -3…-25V DC regarding signal ground (SG) 1, disasserted, OFF, mark, inactive |
Mechanical
Width | 22 mm |
---|---|
Height | 137.85 mm |
Depth | 105.42 mm |
Weight | 175 g |
DIN rail | Compatible zinc-plated chromate-passivated steel DIN rail, You can use the EN50022 – 35 x 7.5 mm (1.38 x 0.30 in) DIN rail |
Environmental
Surrounding air temperature, max | 60 °C |
---|---|
Emissions | IEC 61000-6-4 |
Vibration | 5 G @ 10…500 Hz |
ESD immunity | 6 kV contact discharges, 8 kV air discharges |
EFT/B immunity | ±4 kV @ 5 kHz on power ports, ±3 kV @ 5 kHz on shielded output ports |
Relative humidity | 5…95% noncondensing |
Shock | Operating: 30 G, Non operating: 50 G |
Conducted RF immunity | 10V rms with 1 kHz sine-wave 80% AM from 150 kHz…80 MHz |
Surge transient immunity | ±1 kV line-line (DM) and ±2 kV line-earth (CM) on power ports, ±2 kV line-earth (CM) on shielded output ports |
Operating temperature | 0 °C <Ta <60 °C (32 °F <Ta <140 °F) |
Radiated RF immunity | 10V/m with 1 kHz sine-wave 80% AM from 80…2000 MHz, 10V/m with 200 Hz 50% Pulse 100% AM at 900 MHz, 10V/m with 200 Hz 50% Pulse 100% AM at 1890 MHz, 10V/m with 1 kHz sine-wave 80% AM from 2000…2700 MHz |
Nonoperating temperature | -40 °C |
Certification
North American temperature code | T4 |
---|---|
IECEx temp code | T4 |
Corrosion resistance classification | ISA S71.04 G2 |
Voltage and current
MOD power | 100 mA @ 18…32V DC |
---|---|
MOD power passthrough, max | 9.55 A @ 18…32V DC |
SA power passthrough, max | 9.95 A @ 0…32V DC |
Construction
Enclosure type | None (open-style) |
---|
There are no reviews yet.