Necesitas Ayuda?+52 55 61 22 77 00
Correo: ventas@omegaautomation.com.mx

1420-V2-ENT, Powermonitor 500 Ethernetip Power Meter

USD $3,979.26 - (IVA Incluido) + Envío

5 disponibles

Powermonitor 500 Ethernetip Power Meter

Buy it now
SKU: 1420-V2-ENT

Technical Specifications

Input/Output Specifications

Voltage (by direct connection or VT/PT) 400/600V LL
Input impedance 5(6)A, < 0.2VA
Current overloads 6 A, at 50/60 Hz, Continuous
Control power Range: 100 to 240V AC (48 to 62 Hz)
Voltage overloads 2 × Vnom (where Vnom is the nominal voltage of the module), for 500 ms
Coupling type With CTs
Temperature drift ≤ 200 ppm/°C
Current range (by CT) 5 A nominal (6 A maximum)
Rated inputs System type: 1, 2, or 3-phase
Current type Galvanic insulation with built-in CTs
Method True RMS measurements of distorted wave forms
Sampling rate 3840 samples/second at 60 Hz, 3200 samples/second at 50 Hz
Energy additional errors According to EN62053-21 ANSI C12.1, influence quantities Class B according to EN50470-3, EN62053-23

Input/Outputs

Current sensing Nominal: 5 A
Voltage sensing Nominal: 400V AC LN, 600V AC LL Range: 160 to 480V AC LN RMS, 277 to 830V AC LL RMS

Hardware Features

Height Front dimensions: 96 mm
Width Front dimensions: 96 mm
Accuracy Voltage, nominal: 400V AC LN, 600V AC LL @ 25 °C ±5 °C, R.H. ≤ 60%, 48…62 Hz
Optional Ethernet port supporting EtherNet/IP and Modbus TCP/IP Yes
System and single phase average and maximum variables Yes
Real-time clock function Yes
Run hours counter 8+2 digits
Energy measurements (imported/exported) kWh and kVARh
Front protection degree IP65, NEMA 4X, NEMA 12
Metering values display Four rows with 4 digits
Energy value display Ten digits and the plus/minus sign
Universal power supply 120/240V AC 50/60 Hz or 120/240V DC
Revenue grade energy measurements Per ANSI C12.1 Class 1.0, ANSI C12.1
configurable virtual alarms Up to four configurable virtual alarms
Three-phase (system) variables V(L-L), V(L-N), A, VA, W, VAR, power factor, frequency
Single phase variables V(L-L), V(L-N), A(L), An (calculated), VA, W, VAR, power factor
Class • Class 1 (kWh) according to EN62053-21, • Class B (kWh) according to EN50470-3, • Class 2 (kVARh) according to EN62053-23

General Specifications

Line-neutral RMS Maximum @ 160 to 480V AC
Line-line RMS Maximum @ 277 to 830V AC
Start up current 5
Current sensing model Inominal: 5 A, Imaximum: 6A
Line-neutral voltage In the range Vnom: ±(0.5% RDG +1 digit)
Line-line voltage In the range Vnom: ±(1.0% RDG +1 digit)
Current all models From 0.01 to 0.25 A: ±(1.0% of reading (RDG) + 2 digits From 0.25 to 6 A: ±(0.5% RDG +2 digits)
Real and apparent power From 0.05 to 0.25 A, PF 1: ±(2% RDG +1 digit) From 0.25 to 6A, PF 0.5L, PF1, PF 0.8C: ±(1.0% RDG+1 digit)

Measured Parameters

Crest factor ≤3 (15 A max peak)
Power factor PF: Yes
Reactive energy (kVARh) Class 2 according to EN62053-23, ANSI C12.1
Frequency Hz: Yes
Real energy (kWh) Class 1 according to EN62053-21, ANSI C12.1 Class B according to EN50470-3
Reactive power (kVAR) Yes
Current Yes
Real power (kW) Yes
Apparent power (kVA) Yes
Real power consumption (kWh) Yes
Reactive power consumption (kVARh) Yes
Apparent power consumption (kVAh) Yes
Demand power factor Yes
Demand (kW) Yes
Demand (kVAR) Yes
Demand (kVA) Yes
Voltage Yes

Environmental Specifications

Immunity to radiated electromagnetic fields Test without any current: 30V/m from 80 to 2000 MHz
Storage temperature -30 to +70 °C (-22 to +158 °F) (R.H.P178 < 90% noncondensing @ 40 °C) according to EN62053-21, EN50470-1 and EN62053- 23
Operating temperature -25 to +40 °C (-13 to +104 °F) (R.H. from 0…90% noncondensing @ 40 °C) according to EN62053-21, EN50470-1 and EN62053- 23
Noise rejection CMRR 100 dB, 48 to 62 Hz
Electrostatic discharge 15 kV air discharge
Radio frequency suppression According to CISPR 22
EMC According to EN62052-11
Dielectric strength 4 kV AC rms for 1 minute
Installation category Cat. III (IEC60664, EN60664)
Immunity to conducted disturbances 10V/m from 150 KHz to 80 MHz
Burst On current and voltage measuring inputs circuit: 4 kV
Surge On current and voltage measuring inputs circuit: 4 kV, on ‘L’ auxiliary power supply input: 1 kV

Standard Compliance

Connections Screw-type
Cable cross-section area 2.5 mm2 (14 AWG) max, Screw tightening torque: 0.4 N•m min/0.8 N•m max, Suggested screw tightening torque: 0.5 N•m

Electrical

Ampere meter Yes
Blind power meter Yes
Frequency meter Yes
Pulse counter Yes
Voltmeter Yes
Effective power measurement device Yes

Housing DIN

Pollution degree 2
Screw terminals IP20
Mounting Panel mounting
Depth behind panel Maximum @ 81.7 mm (3.2 in.)
Material ABS, self-extinguishing: UL 94 V-0
Weight Approx 400 g (0.88 lb) (packing included)
Dimensions (WxHxD) Module holder: 96 x 96 x 50 mm (3.78 x 3.78 x 1.97 in.), Digital and analog output type modules: 89.5 x 63 x 16 mm (3.52 x 2.48 x 0.63 in.), Serial and Ethernet Communication type modules: 89.5 x 63 x 20 mm (3.52 x 2.48 x 0.79 in.)

Other Features

Configurable via software tool Yes
Configurable alarms Yes
Voltage rotation phase sequence Yes

Communication

EtherNet/IP and Modbus TCP/IP Yes
Peso 0.596 kg
Dimensiones 16.61 × 10.49 × 10.38 cm

Documentation

RESOURCE PUBLICATION NUMBER
User Manual 1420-UM001

Customers reviews

There are no reviews yet.

Be the first to review “1420-V2-ENT, Powermonitor 500 Ethernetip Power Meter”

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

Search for products

Back to Top
Elegir Moneda
USD Dólar de los Estados Unidos (US)
Product has been added to your cart