Necesitas Ayuda?+52 55 61 22 77 00
Correo: ventas@omegaautomation.com.mx

140M-C2E-B25-KN, Motor Protection Circuit- Breaker

MXN $999,999.00 - (IVA Incluido) + Envío

1 disponibles

Motor Protection Circuit- Breaker

Buy it now
Brands:
SKU: 140M-C2E-B25-KN
With integrated auxiliary switch False
With integrated under voltage release False
Rated short-circuit breaking capacity lcu at 400 V, AC 100 kA
Rated operation power at AC-3, 400 V 0.75 kw
Rated operation power at AC-3, 230 V 0.37 kw
Rated operating voltage 230 A
Type of control element Turn button
Overload release current setting 1.6 A
Type of electrical connection of main circuit Screw connection
Magnetic release current per IEC 33 A
Rated operational current (Ie) per IEC 2.5 A
Magnetic trip current 33 A
Short circuit current (Type 2 coordination), max-inv 50kA @ 480V
Current range 1.6…2.5 A
Ultimate short circuit breaking capacity (Icu) per IEC 6kA @ 690V
Rated service short circuit breaking capacity (Ics) per IEC 6kA @ 690V
Hp rating, max 2Hp @ 575V, 3-phase
Rated operating voltage, max 690V per IEC, SEV, VDE0660
Electrical life cycle (Ie max.) 100000 ops
Short circuit current for combination motor controller with 100-K contactor, max-inv 65 kA @ 480Y/277V, UL 508-Type F
Short circuit current for combination motor controller with 100-C contactor, max-inv 65 kA @ 480Y/277V, UL 508-Type F
Short circuit current for self-protected combination motor controller with 100-C contactor, max-inv 65 kA @ 480Y/277V, UL 508-Type E
Switching of standard motors per IEC 1.8 kW @ 690V, 3-phase
KW rating, max 1.8 kW @ 690V (AC-3), 3-phase
Back up fuse (gG, gL) current rating (if Icc ≥ Icu ) per IEC No back-up fuse required @ 500V
Short circuit current for group motor installation with 100-K contactor, max-inv 65kA @ 480V, UL 508-manual motor controller
Short circuit current for motor disconnect with 100-K contactor, max-inv 65kA @ 480V, UL 508-manual motor controller
Short circuit current for group motor installation with 100-C contactor, max-inv 65kA @ 480V, UL 508-manual motor controller
Short circuit current for motor disconnect with 100-C contactor, max-inv 65kA @ 480V, UL 508-manual motor controller
Rated thermal current 0.1…32A @ 60°C ambient temperature (Ith)-inv
Short circuit current for tap conductor protection, max 65 kA @ 480Y/277V per UL 508-manual motor controller
Short circuit current for combination motor controller, max 65kA @ 480V/277V per UL 508-self-protected (Type E)
Fuse or circuit breaker per NEC, max 450 A, UL 508-manual motor controller
Fuse or circuit breaker rating per NEC, max 450 A, UL 508-manual motor controller with 100-C contactor
Short circuit current for group motor installation, max 65kA @ 480V, UL 508-manual motor controller
Short circuit current for motor disconnect, max 65kA @ 480V, UL 508-manual motor controller
Magnetic release current Fixed setting 13…14 x Ie max. Ie max. = maximum values of setting ranges, (±20 %)
Number of poles 3
With thermal protection True
Phase failure sensitive True
Switch off technique Thermomagnetic
Switching frequency, max 25 ops/h
Trip class 10
Rated frequency 50/60 Hz
Rated supply current 0.1 A
Total power loss (Pv) for circuit breaker at rated load operating temperature-inv 6 W
Phase loss protection Differential release
Fuse or circuit breaker rating with 100-K contactor per NEC, max 450 A, UL 508-manual motor controller
Main circuits/overvoltage category 6kV/III @ rated impulse withstand voltage (Uimp)
Auxiliary circuits/overvoltage category-inv 6kV/III @ rated impulse withstand voltage (Uimp)
Width 45 mm
Depth 74.5 mm
Height 90 mm
Contactor size (Type 2 coordination), min-inv 100-C16 @ 600V
Frame size Frame size C, 32 A
Contactor size, min-inv 100-K05: UL-508-Type F combination motor controller
Device construction Built-in device fixed built-in technique
Degree of protection (IP) IP2X
Weight 317 lb
Mechanical life operations 100000 /h
Breaking capacity Standard breaking capacity
Protection type Adjustable thermal/fixed magnetic (13 x In)
Factory option No circuit-breaker auxiliary or trip contacts
Terminal type Screw connection
Vibration resistance Ops (60068-2-6): 5 G
Shock resistance Transport (60068-2-27): 30 G, 11 ms, all axes
Ambient storage temperature -40 °C
Ambient operating temperature -25 °C
Ambient temperature compensation -20 °C
Site altitude To 2000 N.N.(m)
Moisture heat 40 °C, relative humidity 93 %, 56 d (60068-2-3)-inv
Dry heat 100 °C, relative humidity < 50 %, 7 d (60086-2-2)-inv
Dependence on temperature No current reduction @ 60 °C-inv
Moisture change climate 23 °C/83 % relative humidity and 40 °C/92 % relative humidity, 56 cycles (600068-2-30)-inv
Pollution degree 3
Utilization category Motor starter: AC-3 (IEC60947-4-1)
Overload protection characteristics IEC 60947-4-1 motor protection

Sales Info

Repairable NOT_REPAIRABLE
Preferred Availability false
Quick Turnaround false
Dimension Height 5.08
Lead Time 15
Dimension Width 9.525
Dimension Length 10.668
Stock Status STOCKED
Weight 0.34
Weight Unit KG
Dimension Unit CM

,

With integrated auxiliary switch False
With integrated under voltage release False
Rated short-circuit breaking capacity lcu at 400 V, AC 100 kA
Rated operation power at AC-3, 400 V 0.75 kw
Rated operation power at AC-3, 230 V 0.37 kw
Rated operating voltage 230 A
Type of control element Turn button
Overload release current setting 1.6 A
Type of electrical connection of main circuit Screw connection
Magnetic release current per IEC 33 A
Rated operational current (Ie) per IEC 2.5 A
Magnetic trip current 33 A
Short circuit current (Type 2 coordination), max-inv 50kA @ 480V
Current range 1.6…2.5 A
Ultimate short circuit breaking capacity (Icu) per IEC 6kA @ 690V
Rated service short circuit breaking capacity (Ics) per IEC 6kA @ 690V
Hp rating, max 2Hp @ 575V, 3-phase
Rated operating voltage, max 690V per IEC, SEV, VDE0660
Electrical life cycle (Ie max.) 100000 ops
Short circuit current for combination motor controller with 100-K contactor, max-inv 65 kA @ 480Y/277V, UL 508-Type F
Short circuit current for combination motor controller with 100-C contactor, max-inv 65 kA @ 480Y/277V, UL 508-Type F
Short circuit current for self-protected combination motor controller with 100-C contactor, max-inv 65 kA @ 480Y/277V, UL 508-Type E
Switching of standard motors per IEC 1.8 kW @ 690V, 3-phase
KW rating, max 1.8 kW @ 690V (AC-3), 3-phase
Back up fuse (gG, gL) current rating (if Icc ≥ Icu ) per IEC No back-up fuse required @ 500V
Short circuit current for group motor installation with 100-K contactor, max-inv 65kA @ 480V, UL 508-manual motor controller
Short circuit current for motor disconnect with 100-K contactor, max-inv 65kA @ 480V, UL 508-manual motor controller
Short circuit current for group motor installation with 100-C contactor, max-inv 65kA @ 480V, UL 508-manual motor controller
Short circuit current for motor disconnect with 100-C contactor, max-inv 65kA @ 480V, UL 508-manual motor controller
Rated thermal current 0.1…32A @ 60°C ambient temperature (Ith)-inv
Short circuit current for tap conductor protection, max 65 kA @ 480Y/277V per UL 508-manual motor controller
Short circuit current for combination motor controller, max 65kA @ 480V/277V per UL 508-self-protected (Type E)
Fuse or circuit breaker per NEC, max 450 A, UL 508-manual motor controller
Fuse or circuit breaker rating per NEC, max 450 A, UL 508-manual motor controller with 100-C contactor
Short circuit current for group motor installation, max 65kA @ 480V, UL 508-manual motor controller
Short circuit current for motor disconnect, max 65kA @ 480V, UL 508-manual motor controller
Magnetic release current Fixed setting 13…14 x Ie max. Ie max. = maximum values of setting ranges, (±20 %)
Number of poles 3
With thermal protection True
Phase failure sensitive True
Switch off technique Thermomagnetic
Switching frequency, max 25 ops/h
Trip class 10
Rated frequency 50/60 Hz
Rated supply current 0.1 A
Total power loss (Pv) for circuit breaker at rated load operating temperature-inv 6 W
Phase loss protection Differential release
Fuse or circuit breaker rating with 100-K contactor per NEC, max 450 A, UL 508-manual motor controller
Main circuits/overvoltage category 6kV/III @ rated impulse withstand voltage (Uimp)
Auxiliary circuits/overvoltage category-inv 6kV/III @ rated impulse withstand voltage (Uimp)
Width 45 mm
Depth 74.5 mm
Height 90 mm
Contactor size (Type 2 coordination), min-inv 100-C16 @ 600V
Frame size Frame size C, 32 A
Contactor size, min-inv 100-K05: UL-508-Type F combination motor controller
Device construction Built-in device fixed built-in technique
Degree of protection (IP) IP2X
Weight 317 lb
Mechanical life operations 100000 /h
Breaking capacity Standard breaking capacity
Protection type Adjustable thermal/fixed magnetic (13 x In)
Factory option No circuit-breaker auxiliary or trip contacts
Terminal type Screw connection
Vibration resistance Ops (60068-2-6): 5 G
Shock resistance Transport (60068-2-27): 30 G, 11 ms, all axes
Ambient storage temperature -40 °C
Ambient operating temperature -25 °C
Ambient temperature compensation -20 °C
Site altitude To 2000 N.N.(m)
Moisture heat 40 °C, relative humidity 93 %, 56 d (60068-2-3)-inv
Dry heat 100 °C, relative humidity < 50 %, 7 d (60086-2-2)-inv
Dependence on temperature No current reduction @ 60 °C-inv
Moisture change climate 23 °C/83 % relative humidity and 40 °C/92 % relative humidity, 56 cycles (600068-2-30)-inv
Pollution degree 3
Utilization category Motor starter: AC-3 (IEC60947-4-1)
Overload protection characteristics IEC 60947-4-1 motor protection

Sales Info

Repairable NOT_REPAIRABLE
Preferred Availability false
Quick Turnaround false
Dimension Height 5.08
Lead Time 15
Dimension Width 9.525
Dimension Length 10.668
Stock Status STOCKED
Weight 0.34
Weight Unit KG
Dimension Unit CM
Peso 0.34 kg
Dimensiones 10.66 × 9.52 × 5.08 cm
Documentos
 
 

Customers reviews

There are no reviews yet.

Be the first to review “140M-C2E-B25-KN, Motor Protection Circuit- Breaker”

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

Search for products

Back to Top
Elegir Moneda
MXN Peso mexicano
Product has been added to your cart